Descrizione

Sensor Head
Model EX-016
Type Sensor head
Amplifier unit EX-505
Shape M16, Threaded, Non-shielded
Measuring range 0 to 5 mm
Analogue output Output voltage 0 to 5 V (Output impedance: 100 ?)*1
Impedance 100 ?*2
Output current 4 to 20 mA (Applicable load: 0 to 350 ?)*1
Resolution 0.03% of F.S. (RESPONSE = 3,4)*1
Linearity ±0.3% of F.S. (RESPONSE = 2,3,4)*1
Response time (Response mode) 0.1 ms (RESPONSE = 1), 1 ms (RESPONSE = 2), 10 ms (RESPONSE = 3), 100 ms (RESPONSE = 4)*1
Disconnection alarm output (N.C.) NPN: 100 mA max. (40 V), Residual voltage: 1 V max.*3
Functions Auto-zero function/Auto-span function, Response time selector function/ Preset metal characteristic memory function, Cable length selector function/Interference suppression function
Temperature characteristics 0.03% of F.S./°C*4*1
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
Current consumption 220 mA max.
Environmental resistance Enclosure rating IP67
Ambient temperature -20 to +105 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Weight Approx. 63 g
*1 The above data was obtained using an aluminium target (A5052 t=1 mm). When measuring steel or stainless steel targets, refer to the characteristics of linearity for these materials. *2 The above data was obtained using an aluminum target A5052 t=1 mm 0.04' . When measuring steel or stainless steel targets, refer to the characteristics of linearity for these materials. *3 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter. *4 When the distance between the sensor head and the target is 50% of the measuring range and the operating temperature is 10 to +40°C (EX-008) or 0 to +50°C (EX-016 and EX-022).
''