Descrizione

Liquid-level-detection Fibre Unit
Model FU-94
Type Reflective model fibre unit
Fibre unit length 2 m (cannot be cut)
Minimum bend radius R40 mm*1
Minimum detectable object Liquid*2*3
Repetition accuracy 1 mm or less (for water)
Environmental resistance Pressure resistance -49 kPa to 490 kPa
Ambient temperature -40 to +200 °C
Material Case : fluorocarbon polymer, core fibre : multicomponent glass (inside a fluorocarbon polymer case)
Weight Approx. 90 g
*1 The section 80 mm in length from the tip cannot be bent. *2 It may not be possible to detect some liquids, such as those that have a milky white colour. *3 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.
''