Descrizione

Amplifier Unit, Panel Mount Type, PNP
Model GT2-76P
Output PNP output
Mounting type Panel mount
Main unit/Expansion unit Expansion unit*1
Power consumption Normal 2,200 mW max. (30 V, 73.3 mA max.)
Power saving (Eco) 1,700 mW max. (30 V, 56.7 mA max.)
Display power Measured value display 6 + 1/2-digit 7-segment LED (red)
Other displays 2-colour, 13-level bar LED display (red, green), indicators (red, green)
Display range -199.999.9 to 199.999.9
Display resolution 0.1 ?m
Sampling rate 1,000 times/sec.
Control input Timing/preset/ reset/bank input No-voltage input
Control output HH/HI/GO/LO/LL PNP open collector, 30 V 50 mA or less, residual voltage 1 V or less*1*2
Response time hsp (3 ms), 5 ms, 10 ms, 100 ms, 500 ms, 1 s
Environmental resistance Ambient temperature -10 to +50 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Materials Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC
Power supply / I/O cable 12-core connector connection (Connecting cable included)
Weight Approx. 140 g (including panel mounting bracket, protective front cover and power cable)
*1 When adding expansion units, there are the following restrictions according to the number of connected units. [When 2 to 8 units are connected including the main unit] Power supply voltage: 20 to 30 VDC, Control output current: 20 mA or less, (GT2-71MCN(P) only) Ambient temperature: -10 to 45 °C [When 9 to 15 units are connected including the main unit] Power supply voltage: 20 to 30 VDC, Control output current: 10 mA or less (including the DL-RB1A output current), Residual voltage: 1.5 V or lower, (GT2-71MCN(P) only) Ambient temperature: -10 to 45 °C *2 The GT2-71MCN(P) does not have HH/LL.
''