Descrizione

M12 connector type
Model LR-W500C
Type M12 connector 4-pin type
Detecting distance 30 to 500 mm
Min. spot diameter Adjustable spot Approx. o3.5 mm at 100 mm Approx. o9 mm at 250 mm Approx. o18 mm at 500 mm
Response time 200 µs/1 ms/10 ms/100 ms/500 ms selectable *1
Light source White LED
Mutual interference reduction function Up to 2 units when alternate frequencies set
Timer OFF/ON delay/OFF delay/One-shot
Power supply Power voltage 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Current consumption 65 mA or less (without load) at 24 VDC, 120 mA or less (without load) at 12 VDC *2
I/O Control output NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, remaining voltage: 2 V or less N.O./N.C. selectable *3
External input Tuning /Transmission OFF selectable Short circuit current: 1 mA or less for NPN/2 mA or less for PNP For the applied voltage, see the wiring diagrams in the instruction manual. For the input times, see the time charts in the instruction manual. *3
Protection circuit Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection
Environmental resistance Enclosure rating IP65/IP67 (IEC60529)
Ambient light Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less
Ambient temperature -20 to +50 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 1,000 m/s2, 6 times in each of the X, Y, and Z directions
Material Case: Zinc die cast (Nickel chrome plating), Indicator cover: PPSU, Buttons: PES Lens cover and display: PMMA (scratch-resistant coating), Spot adjustment dial: Iron (triiron tetraoxide coated) Connector ring: PMP, Connector socket: PEI
Weight Approx. 110 g
*1 When alternate frequencies are set, the response time increases by approximately 20%. *2 195 mA or less (at 10 V, with load) *3 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com). If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
''