Descrizione

Amplifier Unit, Main Unit, PNP
Model PS-T1P
Type Main unit
Output PNP
Response time 500 µs
Operation mode LIGHT-ON/DARK-ON (switch-selectable)
Indicator lamp Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Yellow LED
Timer function ON-delay: 40 ms, OFF-delay: 40 ms, Timer OFF (switch-selectable)
External calibration input signal Non-voltage input (contact, solid state)
Control output PNP:100 mA max. (30 V max.) Residual voltage: 1 V max.
Stability output PNP:50 mA max. (30 V max.) Residual voltage: 1 V max. *1
Protection circuit Reverse polarity protection, Over-current protection, Surge absorber
Multiple connections to Expansion units Up to 16 expansion units can be connected (a total of 17 units)
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
Current consumption 35 mA or less
Environmental resistance Ambient temperature -10 to +55 °C (No freezing)*2
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions
Case material Body/Cover: Polycarbonate
Weight Approx. 75 g (including 2 m cable)
*1 Stability output is only provided by the PS-T1 (P). Stability output for the PS-T2 (P)/T0 is sent from the PS-T1, FS-T1, FS-M1 or FS-R0. *2 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected. When 3 to 10 units: -10 to +50 °C (14 to 122 °F) When 11 to 16 units: -10 to +45 °C (14 to 113 °F) When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.
''